Data for: Evaluation of the Beckman Coulter DxC 700 AU Chemistry Analyzer
收藏NIAID Data Ecosystem2026-03-11 收录
下载链接:
https://data.mendeley.com/datasets/5v2fsf2cy7
下载链接
链接失效反馈官方服务:
资源简介:
The supplemental data is related to the article entitled “Evaluation of the Beckman Coulter DxC 700 AU Chemistry Analyzer”. The data provides one lab’s performance with the new Beckman Coulter DxC AU 700 compared to an older Siemen’s Vista 500. Performance characteristics included intra and inter-run precision, linearity/analytical measurement range, method correlation, reference range verification and calculated sigma values. A total of 53 assays including 11 critical care, 19 general chemistries, 11 proteins, 10 urines, and 2 CSF analytes were tested. Herein is a summary of the data for all analytes tested.
本补充数据关联于题为《贝克曼库尔特(Beckman Coulter)DxC 700 AU生化分析仪性能评估》的学术论文。本数据展示了某实验室采用新型贝克曼库尔特DxC AU 700分析仪与旧款西门子(Siemens)Vista 500分析仪的性能对比结果。本次评估的性能指标涵盖批内精密度、批间精密度、线性/分析测量范围、方法相关性、参考区间验证以及计算得到的西格玛(σ)值。本次共测试53项检测项目,其中包含11项急诊检验项目、19项常规生化项目、11项蛋白类检测项目、10项尿液检测项目以及2项脑脊液(Cerebrospinal Fluid, CSF)分析物。下文为本次所有被测分析物的相关数据汇总。
创建时间:
2019-12-02