Source and size of included datasets.
收藏Figshare2025-03-25 更新2026-04-28 收录
下载链接:
https://figshare.com/articles/dataset/Source_and_size_of_included_datasets_/28664336
下载链接
链接失效反馈官方服务:
资源简介:
BackgroundGlucose-6-phosphate dehydrogenase (G6PD) deficiency is the main risk factor for severe haemolysis following treatment with 8-aminoquinolines (8AQ). The World Health Organization recommends G6PD testing prior to 8AQ-based hypnozoitocidal treatment.MethodsWe undertook an individual level meta-analysis of the performance of commercially available quantitative point-of-care diagnostics (PoCs) compared with reference spectrophotometry. A systematic literature search (PROSPERO: CRD42022330733) identified 595 articles of which 16 (2.7%) fulfilled pre-defined inclusion criteria and were included in the analysis, plus an additional 4 datasets. In total there were 12,678 paired measurements analyzed, 10,446 (82.4%) by STANDARD G6PD Test (SD Biosensor, RoK, [SDB]), 2,042 (16.1%) by CareStart G6PD Biosensor (AccessBio, USA, [CSA]), 150 (1.2%) by CareStart Biosensor (WellsBio, RoK [CSW]), and 40 (0.3%) by FINDER (Baebies, USA, [FBA]).FindingsThe pooled sensitivities of the SDB when measuring G6PD activity 96%) for all blood samples and G6PD activity thresholds. Irrespective of the blood samples and thresholds applied, sensitivity of the CSA did not exceed 62%, although specificity remained high at both 30% and 70% thresholds (>88%). Only one study each for CSW and FBA was included. Sensitivities of the CSW were 0.04 (95% CI: 0.01-0.14) and 0.81 (95% CI: 0.71-0.89) at the 30% and 70% thresholds, respectively (venous blood samples). Sensitivities of the FBA were 1.00 (95% CI: 0.29-1.00) and 0.75 (95% CI: 0.19-0.99) at the 30% and 70% thresholds (venous blood samples). Specificities of the CSW and FBA were consistently high (>90%) at both thresholds. Accuracy of the SDB was higher in females at the 30% cut-off (OR: 3.49, p=0.002) and lower in malaria patients at the 70% cut-off (OR: 0.59, p = 0.005).ConclusionsThe SDB performed better than other PoCs. More evidence was available for the performance of the SDB compared to other PoCs, giving higher confidence in its utility in diagnosing G6PD deficiency.
创建时间:
2025-03-25



