在规定充放电制度、以及特定的循环次数下,摩托车启动电池的放电容量保持率、容量衰减情况在高倍率启动放电下电压性能以及对应参数的变化率,同时监控高倍率放电下的5秒电压和90秒电压,监控其对应参数的变化率,用于评估该类型电池在长时间循环放电情况下的启动能力,性能衰减情况、电池性能稳定性分析以及电池使用寿命预测。1.数据来源
在规定的循环寿命测试制度下,循环记录摩托车锂离子13L启动电池1000次的实时容量数据
2.数据处理
2.1实时预警
基于摩托车锂离子启动电池放电容量,容量保持率和电池高倍率放电得到的5秒电压和30秒电压的性能要求,通过设置监测阀值并实现智能预警,当循环至容量保持率<70%的标称容量时结束循环,或者当高倍率放电的5秒电压低于10V或者90秒电压低于7.2V时结束循环。
当测试结束时,若循环记录1000次中均没有预警,则放电容量取1000次的数据;若循环过程中有预警,则采用预警时的数据作为放电容量。
2.2性能衰减变化率
采用以下公式计算摩托车锂离子启动电池性能参数:
(1)放电容量保持率=放电容量/标称容量*100%;
(2)容量衰减率=(初始容量-终止容量)/初始容量;
(3)容量变化率=(终止容量-放电容量)/终止容量;
3.数据应用
通过分析摩托车启动电池的放电容量保持率、容量衰减情况在高倍率启动放电下电压性能以及对应参数的变化率,用于评估该类型电池在长时间循环放电情况下的性能衰减情况、电池性能稳定性分析以及电池使用寿命预测。
This dataset focuses on the discharge capacity retention rate, capacity attenuation, voltage performance during high-rate starting discharge and variation rates of corresponding parameters of motorcycle starting batteries under standardized charge-discharge protocols and specified cycle counts. It also monitors the 5-second and 90-second voltages under high-rate discharge and their variation rates, to evaluate the starting capability, performance attenuation, battery performance stability and service life prediction of this type of battery under long-term cyclic discharge conditions.
1. Data Source
Real-time capacity data of 1000 cycles of 13L lithium-ion motorcycle starting batteries were cyclically recorded under the stipulated cycle life test protocol.
2. Data Processing
2.1 Real-time Early Warning
Based on the performance requirements for discharge capacity, capacity retention rate, and the 5-second and 30-second voltages obtained from high-rate discharge of motorcycle lithium-ion starting batteries, monitoring thresholds were set to enable intelligent early warning. The cycle test will be terminated when: the capacity retention rate is less than 70% of the nominal capacity, the 5-second voltage during high-rate discharge is lower than 10V, or the 90-second voltage is lower than 7.2V.
At the end of the test: if no early warning occurs across the 1000 cycles, the discharge capacity data from the 1000th cycle will be adopted; if early warning occurs during the cycle process, the data at the time of early warning will be used as the final discharge capacity.
2.2 Performance Attenuation Variation Rate
The following formulas are used to calculate the performance parameters of lithium-ion motorcycle starting batteries:
(1) Discharge capacity retention rate = (discharge capacity / nominal capacity) * 100%;
(2) Capacity attenuation rate = (initial capacity - final capacity) / initial capacity;
(3) Capacity variation rate = (final capacity - discharge capacity) / final capacity;
3. Data Application
By analyzing the discharge capacity retention rate, capacity attenuation, voltage performance during high-rate starting discharge and variation rates of corresponding parameters of motorcycle starting batteries, this dataset is applied to evaluate the performance attenuation, battery performance stability and service life prediction of this type of battery under long-term cyclic discharge conditions.