Accurate resampling of radial dose point kernels to a Cartesian matrix for voxelwise dose calculation
收藏资源简介:
Note: The version 1.1 dataset has been corrected to include only accurate kernels. Errors were found in Version 1.0 kernels with the following sizes: 1.953, 2.21, 2.4, 3.9, 4, 4.42, 4.8, and 6.8 mm Cartesian matrix dose point kernels, generated by resampling of prior radial dose point kernels. See accompanying paper for additional details: "<strong>Accurate resampling of radial dose point kernels to a Cartesian matrix for voxelwise dose calculation"</strong> Refer to the upload titled "<em>Kernel_Format_README.xlsx</em>" for details regarding kernel format and modification for use. Source (radial) kernel generation is described in the Medical Physics article titled "Dose point kernels for 2,174 radionuclides." - https://doi.org/10.1002/mp.13789 Source (radial) kernels can be downloaded here: https://doi.org/10.5281/zenodo.2564036