资源简介:
User experience was compared between a new pre-fillable 2.25 mL glass syringe equipped with an ultra-thin-wall (UTW) 8 mm staked needle and a marketed BD Neopak™ syringe equipped with a special-thin-wall (STW) 12.7 mm staked needle. Participants simulated subcutaneous injections with both syringes alone (formative Human Factors study) and in combination with a needlestick-prevention device (validation Human Factors study). Usability results of both studies showed higher success rates for delivering the full dose of 2 mL viscous solution (30 cP) with the 8mmUTW syringe than with the 12.7mmSTW one (63% vs. 42% in the formative study). The use of the 8mmUTW syringe demonstrated also better ease of use and acceptance results and 72% of formative study participants preferred this new syringe over the current one when delivering the viscous solution. Using a shorter needle also showed a benefit in decreasing the injection-related anxiety. Besides, in the case of a non-recommended injection technique, the calculated risk of accidental intramuscular injection is reduced by 2 to 13 times with the 8mmUTW syringe. Altogether, the results obtained demonstrated an improvement of the user experience with this new syringe compared to the current one in the manual delivery of 2 mL viscous solutions.

本研究对比了两款注射器的用户体验:一款为新型预充式2.25 mL超薄壁(ultra-thin-wall, UTW)8mm固定针(staked needle)玻璃注射器,另一款为市售BD Neopak™特薄壁(special-thin-wall, STW)12.7mm固定针注射器。受试者分别单独使用两款注射器进行模拟皮下注射操作(形成性人机工效学研究),并搭配防针刺伤装置(needlestick-prevention device)开展模拟注射操作(验证性人机工效学研究)。两项研究的可用性评价结果均显示,使用8mm UTW注射器完成2 mL 30厘泊(centipoise, cP)粘性溶液全剂量注射的成功率高于12.7mm STW注射器:在形成性研究中,前者成功率为63%,后者为42%。相较于市售款,新型8mm UTW注射器还具备更优异的使用便捷性与用户接受度;在形成性研究中,72%的受试者在注射粘性溶液时更青睐这款新型注射器。使用更短的注射针还可降低注射相关焦虑。此外,当采用非推荐注射技术时,使用8mm UTW注射器可将意外肌内注射的估算风险降低2至13倍。综上,相较于市售注射器,这款新型注射器在手动输送2 mL粘性溶液的场景中,可有效改善用户使用体验。
提供机构:
Taylor & Francis
创建时间:
2020-08-24
二维码
社区交流群
二维码
科研交流群
商业服务