ABSTRACT The ideal cuff pressure (Pcuff) must prevent microaspiration of oropharyngeal secretions due to air leakage and avoid injury to the tracheal mucosa. Usually, monitoring consists of a manometer to keep the Pcuff between 20 and 30cmH2O. The minimal occlusive volume (MOV) method minimally inflates the cuff using a syringe so that no leakage occurs. This study aims to evaluate the ability of the minimal occlusive method to individualize the Pcuff adjustment in mechanically ventilated patients. Cross-sectional prospective study with 25 adult patients with more than 48 hours of mechanical ventilation. Cuff pressure was measured at two moments: initial and by MOV. The prevalence of Pcuff outside the normal range was 76%. Leakage in the initial measurement occurred in 9 patients, 4 of whom were within the reference values. The other 5 patients presented Pcuff<20cmH2O. In the adjustment by the MOV method, all patients presented Pcuff at the limit of normality. Patients without leakage with Pcuff>30cmH2O had a reduction when adjusted for MOV (45.4±9.6 against 28.5±1.6cmH2O; p<0.001). We can conclude that the minimal occlusive volume method was able to individualize the Pcuff within the reference values in all patients.

摘要 理想气囊压力(Pcuff)需既能避免因气体泄漏引发的口咽分泌物微量误吸,又可避免损伤气管黏膜。临床常规采用压力计进行监测,将Pcuff维持在20~30cmH₂O范围内。最小闭合容量(MOV)法通过注射器微量充盈气囊,直至无气体泄漏发生。本研究旨在评估最小闭合容量法对机械通气患者Pcuff的个体化调节效果。本研究为横断面前瞻性研究,纳入25例机械通气时长超过48小时的成年患者,分别于初始状态及采用MOV法调整后两个时间点测量气囊压力。结果显示,初始状态下Pcuff超出正常参考范围的患者比例为76%。初始测量时存在气体泄漏的患者共9例,其中4例的Pcuff处于参考值范围内,其余5例患者的Pcuff低于20cmH₂O。采用MOV法调整后,所有患者的Pcuff均处于正常参考范围区间内。初始无气体泄漏但Pcuff高于30cmH₂O的患者,经MOV法调整后Pcuff显著降低(调整前为45.4±9.6cmH₂O,调整后为28.5±1.6cmH₂O;p<0.001)。综上可知,最小闭合容量法可使所有患者的Pcuff个体化调整至正常参考范围内。
提供机构:
SciELO journals
创建时间:
2023-02-28
二维码
社区交流群
二维码
科研交流群
商业服务