遇见数据集

国产计算机性能测试数据

收藏
浙江省数据知识产权登记平台2024-10-10 更新2024-10-11 收录
官方服务:

资源简介:

对国产计算机硬件施加负荷应力,通过数据交互,监测计算机工作状态,及时评估计算机性能。便于运维人员及时了解计算机的运行稳定性,也可以将运行情况及时向用户反馈,从而迅速有效解决相应问题,维持计算机正常运作。1、数据采集:计算机先进行LTP测试,通过后再进行重启测试,LTP测试数据上传到mysql数据库并保存在mysql服务器中,通过网线端口连接MES服务器,MES系统检索38条数据;重启测试数据则通过国产计算机连续工作中产生的系统日志采集。 2、数据处理:设定单台测试计算机的反馈数据条数和重启次数,重启次数为50次,LTP测试过程反馈数据条数为38条。利用代码IF语句,当设定数值与实际数值相符,该计算机测试过程无故障,赋予老化测试OK结果,故障分类为无;当LTP测试过程反馈数据条数不足38条时,计算机中止于LTP测试,赋予老化NG结果,判定LTP测试失败;当重启次数不足50条时,计算机中止于重启测试,赋予老化NG结果,判定重启测试失败。 4、数据应用:计算机连续工作测试,利用此数据处理分析,可以较简单读取计算机连续工作测试状态,设备运行异常产品故障可以得到较为准确定位,对损坏或其他问题进行即时评估,防止过度维修,误修。

This dataset applies load stress to domestic computer hardware, monitors the operating status of computers via data interaction, and evaluates their performance in a timely manner. It enables operation and maintenance personnel to promptly grasp the operational stability of the computers, and feeds back real-time operating conditions to users, so as to quickly and effectively resolve corresponding issues and maintain the normal operation of the computers. 1. Data Collection: The computers first undergo the LTP test, followed by the reboot test after passing the LTP test. LTP test data is uploaded to and stored in the MySQL database and MySQL server. The computers are connected to the MES server via an Ethernet port, and the MES system retrieves 38 data entries; reboot test data is collected through system logs generated during the continuous operation of domestic computers. 2. Data Processing: Set the number of feedback data entries and reboot times for a single test computer, where the reboot times are set to 50, and the number of feedback data entries during the LTP test is set to 38. Use the IF statement in code: when the set values match the actual values, the computer has no faults during the test process, and the aging test result is assigned as OK with the fault category marked as "none"; when the number of feedback data entries during the LTP test is less than 38, the computer aborts the LTP test, and the aging test result is assigned as NG, declaring the LTP test failed; when the number of reboot times is less than 50, the computer aborts the reboot test, and the aging test result is assigned as NG, declaring the reboot test failed. 4. Data Application: For the continuous operation test of computers, through this data processing and analysis, the status of the computer continuous operation test can be easily acquired. Abnormal equipment operation and product faults can be accurately located, and real-time evaluation can be conducted for damages or other issues, preventing over-maintenance and mistaken maintenance.

创建时间:
2024-09-04
搜集汇总
数据集介绍
国产计算机性能测试数据 数据集图片
特点
国产计算机性能测试数据集包含65529条记录,用于监测和评估国产计算机硬件在负荷应力下的工作状态和性能,便于运维人员及时了解计算机的运行稳定性并解决问题。数据集通过LTP测试和重启测试采集数据,并根据预设规则进行数据处理和应用。
以上内容由遇见数据集搜集并总结生成
二维码
社区交流群
二维码
科研交流群
商业服务